我与么公激情完整视频_亚洲αⅴ无码天堂在线观看_涩涩视频污污成人版_成人免费毛片日韩毛片_国产精品性色综合av_中文字幕网站 五月网站_一级黄片大全_久久精品国产2020超碰_亚洲三级国产影视_av综合色区无码

Foshan Shengbang Steel Structure Co., Ltd.

11 years experience in plant design and construction

Common choice of 1875 sets of steel structure buildings

National service hotline:

0757-81002668
4News

portal frame light steel structure housing support member design requirements

Hits:1978 Time:2016-3-19
  

Steel News Hainan: portal frame light steel structure housing support member design requirements


1, Hainan steel portal frame light steel structure housing the cross bracing and flexible bars can lever design, non-cross-bracing pressurized club member and a rigid tie bar should be pressed design.
2, Frame oblique transverse horizontal support beam internal force, should be supported by the top of the column by horizontal truss calculated longitudinal wind load: do not count for cross bracing struts force.
3, between the frame pillars support the internal forces, it should be listed suffered longitudinal wind load (if the crane, the crane should be counted longitudinal braking force) by the support in the vertical column foot cantilever truss calculated on the basis of the column. For cross-bracing struts force may not count. When the same column column column with a multi-channel support when asked, considering the longitudinal force can be evenly distributed among the support.
4, the support member that is pulled or pushed, should the current national standard. Steel structure design specifications "GB50017 or" cold-formed steel specifications "GB50018 on axial tension or axial compression specified Component.